smallbusinessvasup.blogg.se

Hp smart array p410i controller self test failure
Hp smart array p410i controller self test failure









hp smart array p410i controller self test failure

Physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 750 GB, OK) Now I replaced the failed drive by hotswapping it with the unassigned drive. Continue? (y/n) yīut as you can see, re-enabling the logicaldrive this was not possible. Warning: Any previously existing data on the logical drive may notīe valid or recoverable. ~# /usr/sbin/hpacucli ctrl slot=0 ld 2 modify reenable Open console and type command: hpssacli controller slot0 modify hbamodeon forced.

HP SMART ARRAY P410I CONTROLLER SELF TEST FAILURE HOW TO

So I tried was to reenable the logicaldrive (to add the spare afterwards): How to swicth HP proliant Gen8 P420i smart array controller to hda - mode. I thought maybe the controller put the array into "failed" state due to the missing spare and protects failed arrays from modification. Interestingly it is possible to add the unassigned drive to the first array without problems. A logical disk was made on the RAID array 1 + 0 of 4 disks 146 GB. 1783-Slot 0 Drive Array Controller Failure Self-test failure (cmd 0h, err 00h, loockup 0DEAD: DEADh) The server does not load. Use the "show" command on devices to show additional details When loading the server on the screen, I get the RADI-controller error: Slot 0 HP Smart Array P420i Controller Initializing. ~# /usr/sbin/hpacucli ctrl slot=0 array B add spares=2I:1:8Įrror: This operation is not supported with the current configuration. I first tried to add the unassigned drive 2I:1:8 as a spare to logicaldrive 2, but this was not possible: I noticed the problem due to I/O errors on the host, even if only 1 physicaldrive of the RAID5 is failed.ĭoes someone know why this could happen? The logicaldrive should go into "Degraded" mode but still be fully accessible from the host os!? I thought that I had drive 2I:1:8 configured as a spare for Array A and Array B, but it seems this was not the case :-(. Physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SATA, 750 GB, OK) Physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SATA, 750 GB, OK) Physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SATA, 750 GB, Failed) Physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SATA, 750 GB, OK) The office believes the drive in Bay 8 was configured as a 'hot spare' and automatically rebuilt (I see activity/green. Problem: The drive in Bay 7 has recently failed (Red amber light). Physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SATA, 750 GB, OK) Bays 1 - 8 have: HP 1 TB drives inserted. Physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SATA, 750 GB, OK) Physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SATA, 750 GB, OK) 1783-Slot 3 Drive Smart Array Controller Failure Self-test failure (cmd0h, err00h, lockup0DEAD:DEADh)' 1st thing to mention is that after putting the controller in the server the boot (into the screen where you press f9 for bios f10 for intelligent provisioning etc.) takes 10-15-20 minutes whereas. Physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SATA, 750 GB, OK) Smart Array P400 in Slot 0 (Embedded) (sn: XXXX) ~# /usr/sbin/hpacucli ctrl slot=0 show config This is how it looked when I detected the error: 256 MB Cache/Battery Backup) with a logicaldrive with replaced failed physicaldrive that does not rebuild. This is a production environment so I can't shutdown/reboot the server until this weekend.I have a HP Server with SmartArray P400 controller (incl. The office believes the drive in Bay 8 was configured as a "hot spare" and automatically rebuilt (I see activity/green blinking light on the drive) when Bay 7 failed.Ī replacement HP drive (same part #/size) has been ordered. The drive in Bay 7 has recently failed (Red amber light). Bay's 1 - 8 have: HP 1 TB drives inserted I'm helping an office and they have the following configuration:ĭrive configuration: 8 drives. Hello, I was wondering if I could get some feedback/suggestions regarding a failed RAID hard drive.











Hp smart array p410i controller self test failure